<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Direct &#8211; Idropower</title>
	<atom:link href="https://idropower.co.uk/product-category/heaters/direct/feed/" rel="self" type="application/rss+xml" />
	<link>https://idropower.co.uk</link>
	<description></description>
	<lastBuildDate>Mon, 17 Jun 2024 13:19:07 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://idropower.co.uk/wp-content/uploads/2025/02/new-fav-100x100.jpg</url>
	<title>Direct &#8211; Idropower</title>
	<link>https://idropower.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Master B Range</title>
		<link>https://idropower.co.uk/product/b-range-direct-heater/</link>
					<comments>https://idropower.co.uk/product/b-range-direct-heater/#respond</comments>
		
		<dc:creator><![CDATA[George Marshall]]></dc:creator>
		<pubDate>Fri, 17 Nov 2023 13:53:27 +0000</pubDate>
				<guid isPermaLink="false">https://idropower.co.uk/?product=master-b-range</guid>

					<description><![CDATA[Powerful, Portable, and Efficient Diesel-Powered Heaters]]></description>
										<content:encoded><![CDATA[<p>Welcome to our Master B Range, a collection of high-performance, diesel-powered heaters designed to meet the heating demands of open and semi-open spaces. Whether you are dealing with large warehouses, workshops, or building sites, our Master B heaters are engineered to keep you warm in the toughest conditions. Here&#8217;s an overview of our versatile range:</p>
<h2>1. Master B180: Efficient Heating for Various Environments</h2>
<p>The Master B180 is a direct heater tailored for spaces with thin walls and large openings. With its impressive heating capacity, this model can fill an Olympic-sized swimming pool with heated air in just 97 minutes. Its lightweight design and easy mobility, coupled with simple temperature controls, make it an ideal choice for workshops and open workspaces. <a href="shop/heaters/b180-heater-direct-master-detail">Explore more about Master B180</a></p>
<h2>2. Master B230: Diesel-Powered Excellence in Portability</h2>
<p>Designed for sheds, warehouses, and building sites, the Master B230 offers direct, diesel-powered heating with exceptional portability. With options for both analogue and digital thermostats, this heater ensures ease of use and efficient temperature control. The ability to run continuously for 10 hours guarantees warmth throughout your working day. <a href="shop/heaters/b230-heater-direct-master-detail">Discover the features of Master B230</a></p>
<h2>3. Master B360: Unmatched Heating Power for Large Spaces</h2>
<p>The Master B360 is the heavyweight champion of our range, delivering an incredible 3,300m3 of heated air per hour. Ideal for open and semi-open environments, this heater combines sheer efficiency with impressive volume. Despite its size, the B360 remains highly mobile, allowing you to position it precisely where you need it. <a href="shop/heaters/b360-heater-direct-master-detail">Learn more about Master B360</a></p>
<h2>Why Choose a Master B Model?</h2>
<ul>
<li><strong>Simple to Use:</strong> All Master B models come with straightforward controls, ensuring hassle-free operation.</li>
<li><strong>Incredible Heat Output:</strong> Experience the power of direct, diesel-powered heating with our Master B range.</li>
<li><strong>Portability:</strong> Easy to move and position, these heaters are designed to adapt to your workspace.</li>
<li><strong>Distinctive Design:</strong> Bonus reason – our Master B models resemble sleek jet engines, adding a touch of style to functionality.</li>
</ul>
<h2>Direct vs. Indirect Heating: Making the Right Choice</h2>
<p>Understanding the difference between direct and indirect heating is crucial. Explore our guide to Direct vs. Indirect Heating to make an informed decision based on your specific heating needs.</p>
<p>Enhance your workspace with the Master B Range – where power, portability, and efficiency meet. Choose the model that suits your requirements and experience unparalleled heating performance. Contact us for personalised assistance and to explore our complete range of industrial cleaning equipment and solutions.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://idropower.co.uk/product/b-range-direct-heater/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B360 (Master)</title>
		<link>https://idropower.co.uk/product/b360-heater-direct-master/</link>
					<comments>https://idropower.co.uk/product/b360-heater-direct-master/#respond</comments>
		
		<dc:creator><![CDATA[George Marshall]]></dc:creator>
		<pubDate>Wed, 06 Oct 2021 10:21:37 +0000</pubDate>
				<guid isPermaLink="false">https://idropower.co.uk/?product=b360-master</guid>

					<description><![CDATA[Mobile, direct, oil heater, perfect for open work environments.]]></description>
										<content:encoded><![CDATA[<p>The B360 is the big boy of Master’s direct, diesel-powered heater range. The B360 is designed for open and semi-open spaces, where keeping the cold out is impossible. For example, sheds and warehouses with big open doors and building sites are the environments in which the B360 thrives.</p>
<h1><strong>Feeling hot hot hot</strong></h1>
<p>The advantage of direct heat generation for open and semi-open environments is the sheer efficiency and volume at which they operate. So long as the space is well-ventilated (which open and semi-open spaces tend to be), direct heating does not separate combustion and heat production. This means no heat is lost when trying to separate exhaust and heat. Plus, it means the heat is easy to expulse into the workspace. The result, therefore, is 3’300m3 of heated air being produced an hour.</p>
<h1><strong>Right where you need it</strong></h1>
<p>The B360 might be the biggest of the range, but they’re still mobile. Mounted on a sturdy chassis and frame, boasting chunky wheels and handles, the B360 is still easy to position where you need them.</p>
<h1><strong>Easy to use</strong></h1>
<p>After you’ve got your B360 right where you need it, using it is as simple as turning it on. Available with either an analogue or digital thermostat: set it to your desired temperature and let the heater do the rest. If the temperature drops too low the heater will strike into action. Once back up to the desired temperature, the heater will go into standby.</p>
<h1><strong>3 reasons why you should get a Master B model?</strong></h1>
<ol>
<li aria-level="1">They are simple to use, with no-nonsense controls.</li>
<li aria-level="1">They throw out incredible amounts of heat.</li>
<li aria-level="1">They are incredibly portable.</li>
</ol>
<p>Bonus reason: they look like jet engines.</p>
<h1><strong>Direct vs Indirect Heating</strong></h1>
<p>The difference between direct and indirect heaters is simply how these heaters expel heat. The way to think about a direct and indirect heater, therefore, could be the distinction between an open and closed fireplace. A direct heater is similar to the open fireplace and the indirect heater is similar to the stove.&nbsp;</p>
<h2><strong>Why is the direct heater similar to an open fireplace?</strong></h2>
<p>The direct heater is similar to the open fireplace as it expels heat by throwing out the air that it uses as part of the combustion process. Of course, in a direct heater, the combustion process is cleaner and better protected than in an open fire.&nbsp;</p>
<p>The positives of direct heating are that the heat efficiency is as high as it possibly can be. Less energy is lost as the heat does not have to be transferred. Therefore, the temperature and rate of heat expulsion can be much higher for a direct heater than for an indirect one. The higher efficiency often leads to greater airflow too, meaning the hot air can be thrown quicker and further into an open space.</p>
<p>The negative of direct heating is that the hot air from the heater is essentially the exhaust of the heater. Direct heaters, therefore, are only to be used in well-ventilated spaces.</p>
<h3><strong>Specification&nbsp;Table</strong></h3>
<p><strong>Mobile phone users:&nbsp;</strong>our tables can be easier to read in landscape.</p>
<table>
<tbody>
<tr>
<td style="border: 1px solid #000000;"><strong>Specifications</strong></td>
<td style="border-image: initial; width: 10px; border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>Units</strong></td>
<td style="width: 10px; border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>B180</strong></td>
<td style="width: 10px; border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>B230</strong></td>
<td style="width: 10px; border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>B360</strong></td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Heating Power</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>kW</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">48</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">65</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">111</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Air Flow</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>m2/h</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1550</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">3000</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">3300</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Fuel Autonomy</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>h</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">8</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">10</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">10</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Thermostat</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td colspan="5" style="border: 1px solid #000000; text-align: center;">Analogue or digital</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Fuel consumption</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>l/h</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">4.5</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">6.2</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">10.6</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Power supply</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>V/Hz</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td colspan="3" style="border: 1px solid #000000; text-align: center;">220-240/1ph/50</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">220-240/1ph/50-60</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Electric power</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>kW</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">0.3</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">0.8</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1.06</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Rated current</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>A</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1.5</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">3.5</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">4.6</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Protection</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td colspan="5" style="border: 1px solid #000000; text-align: center;">IP44</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Tank capacity</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>l</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">36</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">65</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">105</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Product size (L x W x H)</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>mm</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1165 x 380 x 550</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1235 x 575 x 790</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1600 x 700 x 940</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Box size (L x W x H)</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>mm</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1200 x 400 x 530</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1200 x 650 x 1000</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1600 x 750 x 1180</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Net/gross weight</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>kg</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">30/34</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">57/72</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">84/105</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Pallet</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">8</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://idropower.co.uk/product/b360-heater-direct-master/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B230 (Master)</title>
		<link>https://idropower.co.uk/product/b230-heater-direct-master/</link>
					<comments>https://idropower.co.uk/product/b230-heater-direct-master/#respond</comments>
		
		<dc:creator><![CDATA[George Marshall]]></dc:creator>
		<pubDate>Wed, 06 Oct 2021 10:21:27 +0000</pubDate>
				<guid isPermaLink="false">https://idropower.co.uk/?product=b230-master</guid>

					<description><![CDATA[Mobile, direct, oil heater, perfect for open work environments.]]></description>
										<content:encoded><![CDATA[<p>The Master B230 is a direct, diesel-powered heater. They are designed for open and semi-open spaces that are difficult to keep warm, such as sheds and warehouses with large open doors, and building sites.&nbsp;</p>
<p>Direct heat generation means the B230 will keep hands and bodies warm no matter the environment. There are no greater efficient means of generating heat. So long as the space is well-ventilated and needs rapid and vast heat supplied to it, the B230 is the solution.</p>
<h1><strong>Portable</strong></h1>
<p>The B230 is easy to move. Mounted on a sturdy frame, with chunky wheels and handles, they’re easy to move and position right where you need them.&nbsp;</p>
<h1><strong>Easy to use</strong></h1>
<p>Once you have your B230 where you need it, it is as simple to use as turning it on and setting the temperature. Available with either an analogue or digital thermostat, once turned on and set to the temperature you want, the heater will turn itself on and off as required. If the temperature drops the heater will strike up and raise the temperature. Once it reaches the desired temperature, it will shut off until it is next required, saving fuel.</p>
<h1><strong>Heat the whole of your working day (and more)</strong></h1>
<p>The B230 can run continually for 10 hours. Therefore, even if you like your open workspace to be like a summer&#8217;s day in the costa del sol, the B230 will be able to keep you warm across your working day.</p>
<h1><strong>3 reasons why you should get a Master B model?</strong></h1>
<ol>
<li aria-level="1">They are simple to use, with no-nonsense controls.</li>
<li aria-level="1">They throw out incredible amounts of heat.</li>
<li aria-level="1">They are incredibly portable.</li>
</ol>
<p>Bonus reason: they look like jet engines.</p>
<h1><strong>Direct vs Indirect Heating</strong></h1>
<p>The difference between direct and indirect heaters is simply how these heaters expel heat. The way to think about a direct and indirect heater, therefore, could be the distinction between an open and closed fireplace. A direct heater is similar to the open fireplace and the indirect heater is similar to the stove.&nbsp;</p>
<h2><strong>Why is the direct heater similar to an open fireplace?</strong></h2>
<p>The direct heater is similar to the open fireplace as it expels heat by throwing out the air that it uses as part of the combustion process. Of course, in a direct heater, the combustion process is cleaner and better protected than in an open fire.&nbsp;</p>
<p>The positives of direct heating are that the heat efficiency is as high as it possibly can be. Less energy is lost as the heat does not have to be transferred. Therefore, the temperature and rate of heat expulsion can be much higher for a direct heater than for an indirect one. The higher efficiency often leads to greater airflow too, meaning the hot air can be thrown quicker and further into an open space.</p>
<p>The negative of direct heating is that the hot air from the heater is essentially the exhaust of the heater. Direct heaters, therefore, are only to be used in well-ventilated spaces.</p>
<h2><strong>Why is the indirect heater similar to a fireplace stove?</strong></h2>
<p>An indirect heater is similar to a fireplace stove as the heat generated in combustion is separated from the heat expelled by the heater.</p>
<p>The positives of indirect heating are that the hot air is clean as the exhaust is expelled separately. An indirect heater, therefore, can be used to heat closed spaces with less ventilation (so long as the exhaust is flue or outside of the space you want heating). It is common, therefore, for an indirect heater to be placed externally to a space, where the exhaust can be freely dispersed via a chimney. Or, for the heater to be fitted with a flue that pipes the exhaust to a space where it can disperse. The hot air is then flued into the location you want heating up.</p>
<p>The negative of indirect heating is reduced efficiency in comparison to direct heaters. The heat generated in combustion needs to be transferred across a protective material, before being expelled from the heater. As efficient as it can be, this transfer process naturally incurs a reduction in heating potential.</p>
<h3>3 reasons why you should get a&nbsp;Master B model?</h3>
<ol>
<li>They hold up to 10-hours worth of fuel.</li>
<li>They boast no-nonsense controls: one switch for on and off (+ optional thermostat).</li>
<li>They have&nbsp;a portable design, with sturdy wheels, making them easy to transport around work sites.</li>
</ol>
<p><strong>(Bonus reason: they look like jet engines.)</strong></p>
<h3>Specification&nbsp;Table</h3>
<p><strong>Mobile phone users:&nbsp;</strong>our tables can be easier to read in landscape.</p>
<table>
<tbody>
<tr>
<td style="border: 1px solid #000000;"><strong>Specifications</strong></td>
<td style="border-image: initial; width: 10px; border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>Units</strong></td>
<td style="width: 10px; border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>B180</strong></td>
<td style="width: 10px; border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>B230</strong></td>
<td style="width: 10px; border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>B360</strong></td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Heating Power</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>kW</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">48</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">65</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">111</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Air Flow</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>m2/h</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1550</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">3000</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">3300</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Fuel Autonomy</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>h</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">8</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">10</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">10</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Thermostat</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td colspan="5" style="border: 1px solid #000000; text-align: center;">Analogue or digital</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Fuel consumption</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>l/h</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">4.5</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">6.2</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">10.6</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Power supply</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>V/Hz</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td colspan="3" style="border: 1px solid #000000; text-align: center;">220-240/1ph/50</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">220-240/1ph/50-60</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Electric power</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>kW</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">0.3</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">0.8</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1.06</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Rated current</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>A</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1.5</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">3.5</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">4.6</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Protection</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td colspan="5" style="border: 1px solid #000000; text-align: center;">IP44</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Tank capacity</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>l</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">36</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">65</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">105</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Product size (L x W x H)</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>mm</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1165 x 380 x 550</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1235 x 575 x 790</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1600 x 700 x 940</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Box size (L x W x H)</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>mm</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1200 x 400 x 530</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1200 x 650 x 1000</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1600 x 750 x 1180</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Net/gross weight</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;"><strong>kg</strong></td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">30/34</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">57/72</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">84/105</td>
</tr>
<tr>
<td style="border: 1px solid #000000;"><strong>Pallet</strong></td>
<td style="border: 1px solid #000000;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">8</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1</td>
<td style="border: 1px solid #000000; text-align: center;">&nbsp;</td>
<td style="border: 1px solid #000000; text-align: center;">1</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://idropower.co.uk/product/b230-heater-direct-master/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B180 (Master)</title>
		<link>https://idropower.co.uk/product/b180-heater-direct-master/</link>
					<comments>https://idropower.co.uk/product/b180-heater-direct-master/#respond</comments>
		
		<dc:creator><![CDATA[George Marshall]]></dc:creator>
		<pubDate>Wed, 24 Mar 2021 10:33:13 +0000</pubDate>
				<guid isPermaLink="false">https://idropower.co.uk/?product=b180-master</guid>

					<description><![CDATA[Mobile, direct, oil heater, perfect for open work environments.]]></description>
										<content:encoded><![CDATA[<p>The Master B180 is a direct heater designed for providing large amounts of heat to unoccupied, open and semi-open spaces. It is a popular solution in places like workshops and warehouses where big open doors and thin walls let a lot of heat out.</p>
<p>Being a direct heater (see Direct vs Indirect Heating below), the B180 can generate heat with great efficiency and with great volume. The B180, for example, could fill an Olympic Swiming Pool (2’500’000 litres) with heated air in 97-minutes. Or, what we like to call a football match, plus Fergie time. You can see then, that the B180 is more than capable of keeping you toastie on a cold winter’s day.</p>
<p>Direct heaters, including the B180, must be used in well-ventilated spaces (see direct vs indirect heating).</p>
<h1><strong>Easy-to-move</strong></h1>
<p>B180s are lightweight (34kg) heaters. However, to make moving them even easier they are fitted on a trolley with large wheels, making it easier for you to move and position your heater right where you need it.&nbsp;</p>
<h1><strong>Simple to control</strong></h1>
<p>Once positioned where you would like it, you can set your B180 to a temperature that you would like it to maintain. Simply set its thermostat to your desired temperature and crack on with your work. The B180 will then regulate the temperature of your workspace, keeping your fingers nimble and thawed for tinkering.</p>
<h1><strong>Keep yourself warm the whole working day</strong></h1>
<p>Brim its tank and your B180 can run continually for 8 hours. Therefore, even if you like your workspace to be a sauna, the B180 can keep it toasty all day long. If you prefer not to sweat in winter, then it’ll go even longer: using its thermostat to regulate a steady temperature.</p>
<h1><strong>3 reasons why you should get a Master B model?</strong></h1>
<ol>
<li aria-level="1">They are simple to use, with no-nonsense controls.</li>
<li aria-level="1">They throw out incredible amounts of heat.</li>
<li aria-level="1">They are incredibly portable.</li>
</ol>
<p>Bonus reason: they look like jet engines.</p>
<h1><strong>Direct vs Indirect Heating</strong></h1>
<p>The difference between direct and indirect heaters is simply how these heaters expel heat. The way to think about a direct and indirect heater, therefore, could be the distinction between an open and closed fireplace. A direct heater is similar to the open fireplace and the indirect heater is similar to the stove.&nbsp;</p>
<h2><strong>Why is the direct heater similar to an open fireplace?</strong></h2>
<p>The direct heater is similar to the open fireplace as it expels heat by throwing out the air that it uses as part of the combustion process. Of course, in a direct heater, the combustion process is cleaner and better protected than in an open fire.&nbsp;</p>
<p>The positives of direct heating are that the heat efficiency is as high as it possibly can be. Less energy is lost as the heat does not have to be transferred. Therefore, the temperature and rate of heat expulsion can be much higher for a direct heater than for an indirect one. The higher efficiency often leads to greater airflow too, meaning the hot air can be thrown quicker and further into an open space.</p>
<p>The negative of direct heating is that the hot air from the heater is essentially the exhaust of the heater. Direct heaters, therefore, are only to be used in well-ventilated spaces.</p>
<h2><strong>Why is the indirect heater similar to a fireplace stove?</strong></h2>
<p>An indirect heater is similar to a fireplace stove as the heat generated in combustion is separated from the heat expelled by the heater.</p>
<p>The positives of indirect heating are that the hot air is clean as the exhaust is expelled separately. An indirect heater, therefore, can be used to heat closed spaces with less ventilation (so long as the exhaust is flue or outside of the space you want heating). It is common, therefore, for an indirect heater to be placed externally to a space, where the exhaust can be freely dispersed via a chimney. Or, for the heater to be fitted with a flue that pipes the exhaust to a space where it can disperse. The hot air is then flued into the location you want heating up.</p>
<p>The negative of indirect heating is reduced efficiency in comparison to direct heaters. The heat generated in combustion needs to be transferred across a protective material, before being expelled from the heater. As efficient as it can be, this transfer process naturally incurs a reduction in heating potential.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://idropower.co.uk/product/b180-heater-direct-master/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
